Watlow's new EZ-Zone ST integrated control loop solid state controller offers complete thermal system control in a single package solution. You get a PID temperature controller already connected to a high amperage solid state relay with the option of adding a properly sized heat sink, an over/under temperature limit, a shut-down power contactor, digital communications and a remote user interface in one complete and professionally engineered product. Your life just became a whole lot easier when it comes to solving the thermal requirements of your system.

Because the system is modular and scalable, you only pay for what you need. You can stack the EZ-Zone ST integrated thermal loop into multiple configurations giving you the flexibility to standardize on the product's platform to solve your wide range of application needs.

Features and Benefits

  • Back panel or DIN-Rail mount - provides several mounting options.
  • Compact package - reduces panel size.
  • Touch-safe package - complies to IP2X which increases safety for user.
  • +/- 0.1 Percent temperature accuracy - provides efficient and accurate temperature control.
  • Agency approvals: UL, CSA, CE, RoHS, WEEE - Meets applications requiring agency approvals.
  • EZ-Zone ST P3T Armor Sealing System Remote User Interface (RUI) -
    • Complies to NEMA 4X, UP65 RUI.
    • Offers water and dust resistance, can be cleaned and washed down.
  • Three-year warranty - demonstrates Watlow's reliability and product support.
  • Off the shelf designed system solution
    • Improves system reliability and termination reduction.
    • Reduces installation cost
    • Eliminates compatibility headaches often encountered with using many different components and brands.
  • Advanced controllability algorithms - offers TRU-TUNE+ for meeting demanding controllability requirements.
  • Profile capability - Includes ramp and soak with four files and 40 total steps.
  • Solid state relay output - Allows faster cycling, more precise control, increased heater life and energy efficiency.
  • PID temperature control
    • Provides accurate temperature control
    • Allows single input/dual output
    • Allows standard PID or advanced PID tuning algorithms
  • Optional 485 Modbus RTU communication - Allows network connectivity to PC or PLC.
  • Optional temperature limit - Increases safety in under/overtemperature condition
  • Optional definite purpose mechanical contactor - Enables circuit safety shut down driven by limit control or PID alarm output signal
  • Optional current monitoring feature - Detects heater current flow and alarm indication of failed Solid State Relay (SSR) or heater zone.
  • Optional Remote User Interface (RUI)
    • Use one RUI for multiple zone solutions to save costs
    • Fits in small places due to shallow panel depth
    • Eliminates costs and complexity of having to bring all controller related wires to front panel area
    • Enables use of multiple remote user interfaces to improve usability of system
  • Optional SSR heat sink
    • Sized and engineered for specific applications
    • Factory supplied heat sink provides UL listed benefits
  • System diagnostics - Provides continuous self-monitoring alerts when there is any system trouble to reduce maintenance and system costs
  • PC Software - EZ-Zone ST Configurator
    • Wizard style configuration of controller settings
    • On-line or off-line recipe editing

Specifications

  • Line Voltage/Power
    • 100 to 240V (AC), +1-/-15 percent; (85-264V (AC)), 50/60 Hz, +/- 5 percent.
    • 24V (AC/DC), +10/-15 percent; 50/60 Hz, +/- 5 percent.
    • 12 VA maximum power consumption without mechanical contactor in system
    • 50 VA maximum power consumption with mechanical contactor used in system, 140VA if using external contactor
    • Data retention upon power failure via nonvolatile memory
  • Environment
    • -18 to 70 C (0 to 149 F) operating temperature
    • -40 to 85 C (-40 to 185 F) storage temperature
    • 0 to 90 percent RH, non-condensing
  • Accuracy
    • Calibration accuracy and sensor conformity: +/- 0.1 percent of span, +/- 1 deg C at the calibrated ambient temperature and rated line voltage.
    • Types R, S, B; 0.2 percent
    • Type T below -50 C; 0.2 percent
    • Calibration ambient temperature at 25 deg C +/- 3 deg C
    • Accuracy span: 540 deg C (1000 F) minimum
    • Temperature stability: +/- 0.1 C/C (+/- 0.1 F/F) rise in ambient maximum
  • Agency approvals
    • UL, CSA, CE, IP65/NEMA 4X indoor use RUI, RoHS, WEEE
    • Limit version features FM approval
  • Controller
    • Microprocessor based user selectable control modes
    • PID module: Single universal input, 2 outputs
    • Limit module: Single universal input, 2 outputs
    • Two total additional digital input/outputs shared between PID and limit functions
    • Control sampling rates: input = 10 Hz, outputs = 10 Hz
    • Isolated EIA 485 Modbus RTU serial communications
  • Wiring Termination - Touch Safe Terminals
    • Input, power and controller output terminals touch safe removable 12 to 22 AWG
    • Power load terminals 6 to 12 AWG
    • Tightening torque: 30 in.-lbs.
  • Universal Input
    • Thermocouple, grounded or ungrounded sensors
      • 20 MΩ source resistance
      • Maximum of 20Ω source resistance
    • RTD 2- or 3-wire, platinum, 100Ω and 1000Ω @ 0 C calibration to DIN curve (0.00385 Ω/Ω/C)
    • Process, 0-20 mA @ 100Ω, or 0-10 V (DC) @ 20 kΩ input impedance; scalable, 0-50 mV
    • Inverse scaling
  • Digital Input
    • Update rate 1 Hz
    • Dry contact or DC voltage
    • DC Voltage
      • Maximum input 36V at 3 mA
      • Minimum high state 3V at 0.25 mA
      • Maximum low state 2V
    • Dry contact
      • Maximum short circuit 13 mA
      • Minimum open resistance 500Ω
      • Maximum closed resistance 100Ω
  • Current Measurement
    • Accuracy +/- 15 percent of displayed value
    • Accuracy range 5 to 50A
    • Operating range 2 to 50A
  • Digital Output
    • Update rate 1 Hz
    • Output voltage 24V, current limit 10 mA
  • Allowable Operating Range
    • Type J: 0 to 815 C, 32 to 1500 F
    • Type K: -200 to 1370 C, -328 to 2500F
    • Type T: -200 to 400 C, -328 to 750F
    • Type N: 0 to 1300C, 32 to 2372 F
    • Type E: -200 to 800 C, -328 to 1470 F
    • Type C: 0 to 2315 C, 32 to 4200 F
    • Type D: 0 to 2315 C, 32 to 4200 F
    • Type F: 0 to 1395 C, 32 to 2543 F
    • Type R: 0 to 1760 C, 32 to 3200 F
    • Type S: 0 to 1760 C, 32 to 3200 F
    • Type B: 0 to 1816 C, 32 to 3300 F
    • RTD (DIN): -200 to 800 C, -328 to 1472 F
    • Process: -1999 to 9999 units
  • Output Hardware
    • User selectable for heat/cool as on-off, P, PI, PD, PID, or alarm action. Not valid for limit controls
    • Electromechanical relay. Form A, rated 2A
    • SSR drive 20-28V (DC) low side open collector switch
    • SSR, Form A, 0.5A @ 24V (AC) minimum, 264V (ac) maximum, opto-isolated, without contact suppression.
    • Electromechanical relay, Form A, rated 5A, auxiliary output on PID module, output 2
    • Electromechanical relay, Form C, rated 5A, auxiliary output on limit module, output 3

Specifications for Basic Remote User Interface (RUI)

  • Operator Interface
    • Dual 4 digit, 7 segment LED displays
    • Forward, backward, up and down keys plus a customer programmable function key
    • Typical display update rate 1 Hz
    • Agency approved to IP65/NEMA 4X
  • Line Voltage/Power
    • 100 to 240V (AC), +10/-15 percent; (85-264V (AC)), 50/60 Hz, +/- 5 percent
    • 24V (AC/DC), +10/-15 percent; 50/60 Hz, +/- 5 percent

Specifications for Mechanical Contactor

  • Insulation class: UL class B 130 C (266 F)
  • Minimum load of 100 watts
  • Duty cycle: continuous
  • Contact Ratings:
    Full Load Amps Number Of Poles Line Voltage Locked Rotor Amps Resistive Amp Rating Maximum
    Horsepower
     
    40 2 240/277 240 50 120V 1 Ph 2 HP  
        480 200 50 240V 1 Ph 3 HP  
        600 160 50    
                 